| System Info |
| Gallons (or liters) per minute at point of chlorine
injection: |
Gallons
Liters |
| Applied chlorine dosage in parts per million: |
|
| Pressure at point of injection in psi: |
|
| Is flow rate variable? |
yes
no |
| Estimated contact time in minutes: |
|
| Water temperature estimated: |
Fahrenheit
Celsius |
pH:
Iron PPM:
Manganese PPM:
Odor?
Coliform?
Fecal coliform?
|
| Helpful Information |
| GPM = Gallons per minute
at point of chlorine injection |
| RESIDUAL = amount of
chlorine remaining after contact with water and its impurities.
A residual of .2 -.6 PPM should remain after chlorination at point
of use. |
| CONTACT TIME - the
time required for chlorine contact to perform disinfection. |
| APPLIED CHLORINE DOSAGE
= desired chlorine feed rate for water conditions. See chart below. |
| Water
Temperature 50 Degrees F |
Water
Temperature 32 to 40 Degrees F |
Contact time
in munutes |
Necessary chlorine residual (ppm) |
Contact time
in munutes |
Necessary chlorine residual (ppm) |
| pH 7 |
pH 7.5 |
pH 8 |
pH 7 |
pH 7.5 |
pH 8 |
| 40 |
0.3 |
0.5 |
0.6 |
40 |
0.2 |
0.3 |
0.4 |
| 30 |
0.4 |
0.6 |
0.8 |
30 |
0.3 |
0.4 |
0.5 |
| 20 |
0.6 |
0.9 |
1.2 |
20 |
0.4 |
0.6 |
0.8 |
| 10 |
1.2 |
1.8 |
2.4 |
10 |
0.8 |
1.2 |
1.6 |
| 5 |
2.4 |
3.6 |
4.8 |
5 |
1.6 |
2.4 |
3.2 |
| 2 |
6.0 |
9.0 |
12.0 |
2 |
4.0 |
6.0 |
8.0 |
| 1 |
6.0 |
18.0 |
24.0 |
1 |
8.0 |
12.0 |
16.0 |
|
| Metering Pump Selection |
| Select metering pump by taking total
gallons or liters used per day (meaning 24 hours of well pump
run time), and selecting a metering pump that most closely matches
this requirement. For instance, if 2.4 gallons of chloirne are
needed per day, select a 10 gallon per day pump. Then set the
pump at 24% of rated pump by adjusting the speed and/or stroke
settings on the pump. |
| Impurities Affecting Chlorine
Demand |
| IRON:
Apply 1 ppm chlorine for each 1.0 ppm iron |
| MANGANESE:
Apply 1.7 to 2.0 ppm chlorine for each 1 ppm manganese. |
| HYDROGEN
SULFIDE: Apply 2.0 ppm chlorine for each 1 ppm hydrogen
sulfide. |
| OTHER
factors that can affect chlorine demand: color, sediment, turbidity,
oil to name a few. |
| Variable Flow Rates |
| Note: if the water stream into which
the chlorine is being injected varies, determine the maximum flow
rate, and use a proportionally fed chlorination system. |
| Chlorine Bleach (sodium
hypochlorite) |
| Household
bleach = 5 1/4% 52,500 PPM |
| Pool chlorine
= 12% or 120,000 PPM |
| Pool chlorine
dilutions: |
| Diluted 1 part chlorine to 9 parts water:
12,000 |
| Diluted 1 part chlorine to 18 parts
water: 6,000 |
| Note: use soft
or purified water when diluting chlorine bleach. |
| How many gallons or liters
per day of bleach you would use: |
Type the calculation result from the calculator
in the right of this page:
Gallons
Liters |
| Please tell us background
information or notes here: |
|
| Disclaimer: |
| The information contained here is believed
to be reliable and offered in good faith with no warranties or
implied warranties or fitness for a particular use. System design
suggestions are based on best judgement or estimates considering
limited information provided by customer; End-user or the customer
is responsible for determining suitability of application and
usage under site-specific circumstances, environmental conditions
and water quality profile. The customer is responsible for determining
that Information in this document is appropriate for the specific
application, and ensuring compliance with applicable laws and
regulations. Installation by a qualified mechanical contractor
/ plumber, and ongoing sampling and monitoring protocol is required
for all installations to determine actual performance and the
appropriate frequency of service. Advanced Water Systems Inc.
neither accepts or assumes any liability associated with water
treatment system design. No warranty or guarantees are extended
to cover piping systems, appliances or other water using fixtures.
I agree to hold harmless Advanced Water Systems Inc for any information
contained herein and take full responsibility for my own water
systems and applications. |
I agree
I
do not agree |
|